0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6ES7 214 1AD23 0XB0

6ES7 214 1AD23 0XB0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 6ES7 214 1AD23 0XB0 - CPU, 14 INPUTS, 10 OUTPUTS, 24VDC

  • 数据手册
  • 价格&库存
6ES7 214 1AD23 0XB0 数据手册
Product data sheet 6ES7214-1AD23-0XB0 SIMATIC S7-200, CPU 224, COMPACT UNIT, DC POWER SUPPLY 14 DI DC/10 DO DC, 8/12 KB CODE/8 KB DATA, PROFIBUS DP EXTENDABLE - Supply voltage 24 V DC Yes permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Load voltage L+ Rated value (DC) 24 V permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Input current Inrush current, max. 12 A ; at 28.8 V from supply voltage L+, max. 700 mA ; 110 to 700 mA, output current for expansion modules (DC 5 V) 660 mA Encoder supply 24 V encoder supply 24 V Yes ; permissible range: 15.4 to 28.8 V Short-circuit protection Yes ; electronic at 280 mA Output current, max. 280 mA Memory Type of memory 6ES7214-1AD23-0XB0 Page 1/ 6 other 01/28/2014 subject to modifications © Copyright Siemens AG 2014 Number of memory modules (optional) 1 ; pluggable memory module, content identical with integral EEPROM; can additionally store recipes, data logs and other files Data and program memory Data memory, max. 8 kbyte Program memory, max. 12 kbyte ; 8 KB with active run-time edit Backup present Yes ; Program: Entire program maintenance-free on integral EEPROM, programmable via CPU; data: Entire DB 1 loaded from PG/PC maintenance-free on integral EEPROM, current values of DB 1 in RAM, retentive memory bits, timers, counters, etc. maintenancefree via high-performance capacitor; optional battery for long-term buffering Battery Backup battery Battery operation Backup time, max. 100 h ; (min. 70 h at 40 °C); 200 days (typ.) with optional battery module CPU processing times for bit operations, max. 0.22 µs Counters, timers and their retentivity S7 counter Number 256 of which retentive with battery adjustable Yes ; via high-performance capacitor or battery lower limit 1 upper limit 256 Counting range lower limit 0 upper limit 32767 S7 times Number 256 of which retentive with battery adjustable Yes ; via high-performance capacitor or battery upper limit 64 Time range lower limit 1 ms upper limit 54 min ; 4 timers: 1 ms to 30 s; 16 timers: 10 ms to 5 min; 236 timers: 100 ms to 54 min Data areas and their retentivity Flag Number, max. 6ES7214-1AD23-0XB0 Page 2/ 6 32 byte 01/28/2014 subject to modifications © Copyright Siemens AG 2014 Retentivity available Yes ; M 0.0 to M 31.7 of which retentive with battery 0 to 255, via high-performance capacitor or battery, adjustable of which retentive without battery 0 to 112 in EEPROM, adjustable Hardware configuration Expansion devices, max. 7 ; Only expansion modules of the S7-22x series can be used. Due to the limited output current, the use of expansion modules may be limited. Connectable programming devices/PCs SIMATIC PG/PC, standard PC Expansion modules Analog inputs/outputs, max. 35 ; max. 28 inputs and 7 outputs (EM) or max. 0 inputs and 14 outputs (EM) Digital inputs/outputs, max. 168 ; max. 94 inputs and 74 outputs (CPU + EM) AS-Interface inputs/outputs max. 62 ; AS-Interface A/B slaves (CP 243-2) Digital inputs Number of digital inputs 14 m/p-reading Yes ; optionally, per group Input voltage Rated value, DC 24 V for signal "0" 0 to 5 V for signal "1" min. 15 V Input current for signal "1", typ. 2.5 mA Input delay (for rated value of input voltage) for standard inputs Parameterizable Yes ; all at "0" to "1", min. 0.2 ms at "0" to "1", max. 12.8 ms for interrupt inputs Parameterizable Yes ; I 0.0 to I 0.3 for counter/technological functions Parameterizable Yes ; (E0.0 to E1.5) 30 kHz Cable length Cable length, shielded, max. 500 m ; Standard input: 500 m, high-speed counters: 50 m Cable length unshielded, max. 300 m ; not for high-speed signals Digital outputs Number of digital outputs 10 ; Transistor short-circuit protection No ; to be provided externally Limitation of inductive shutdown voltage to 1W Switching capacity of the outputs 6ES7214-1AD23-0XB0 Page 3/ 6 01/28/2014 subject to modifications © Copyright Siemens AG 2014 with resistive load, max. 0.75 A on lamp load, max. 5W Output voltage for signal "1", min. 20 V DC Output current for signal "1" rated value 750 mA for signal "0" residual current, max. 10 µA Output delay with resistive load "0" to "1", max. 15 µs ; of the standard outputs, max. (Q0.2 to Q1.1) 2 µs; of the pulse outputs, max. (Q0.0 to Q0.1) 2 µs "1" to "0", max. 130 µs ; of the standard outputs, max. (Q0.2 to Q1.1) 10 µs; of the pulse outputs, max. (Q0.0 to Q0.1) 10 µs Parallel switching of 2 outputs for increased power Yes Switching frequency of the pulse outputs, with resistive load, max. 20 kHz ; Q0.0 to Q0.1 Aggregate current of outputs (per group) all mounting positions up to 40 °C, max. 6A horizontal installation up to 55 °C, max. 6A Relay outputs Max. number of relay outputs, integrated 0 Cable length Cable length, shielded, max. 500 m Cable length unshielded, max. 150 m Analog inputs Number of analog potentiometers 2 ; Analog potentiometer; resolution 8 bit Encoder Connectable encoders 2-wire sensor Permissible quiescent current (2-wire sensor), max. Yes 1 mA 1st interface Type of interface Integrated RS 485 interface Physics RS 485 Functionality MPI 6ES7214-1AD23-0XB0 Page 4/ 6 Yes ; As MPI slave for data exchange with MPI masters (S7-300/S7400 CPUs, OPs, TDs, Push Button Panels); S7-200-internal CPU/CPU communication is possible in the MPI network with restrictions; transmission rates: 19.2/187.5 kbit/s 01/28/2014 subject to modifications © Copyright Siemens AG 2014 PPI Yes ; with PPI protocol for program functions, HMI functions (TD 200, OP), S7-200-internal CPU/CPU communication ; transmission rates 9.6/19.2/187.5 kbit/s Serial data exchange Yes ; As freely programmable interface with interrupt facility for serial data exchange with third-party devices with ASCII protocol transfer rates: 1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbit/s; the PC/PPI cable can also be used as RS232/RS485 converter MPI Transmission rate, min. 19.2 kbit/s Transmission rate, max. 187.5 kbit/s Integrated Functions Number of counters 6 ; High-speed counters (30 kHz each), 32 bits (incl. sign), can be used as up/down counters or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counters)); parameterizable enable and reset input; interrupt facilities (incl. call of subroutine with any content) when the setpoint is reached; reversal in counting direction, etc. Counter frequency (counter) max. 30 kHz Number of alarm inputs 4 ; 4 rising edges and/or 4 falling edges Number of pulse outputs 2 ; High-speed outputs, 20 kHz, with interrupt option; pulse-width and frequency modulation option Limit frequency (pulse) 20 kHz Galvanic isolation Galvanic isolation digital inputs between the channels Yes between the channels, in groups of 6 and 8 Galvanic isolation digital outputs between the channels Yes ; Optocoupler between the channels, in groups of 5 Permissible potential difference between different circuits 500 V DC between 24 V DC and 5 V DC Degree and class of protection IP20 Yes Ambient conditions Environmental conditions For further environmental conditions, see "Automation System S7200, System Manual" Operating temperature horizontal installation, min. 0 °C horizontal installation, max. 55 °C vertical installation, min. 0 °C vertical installation, max. 45 °C Air pressure permissible range, min. 6ES7214-1AD23-0XB0 Page 5/ 6 860 hPa 01/28/2014 subject to modifications © Copyright Siemens AG 2014 permissible range, max. 1080 hPa Relative humidity Operation, min. 5% Operation, max. 95 % ; RH class 2 in accordance with IEC 1131-2 Configuration programming Command set Bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, transmissions instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions, integer maths, floating-point math instructions, numerical functions Program processing free cycle (OB 1), interrupt-controller, time-controlled (1 to 255 ms) Program organization 1 OB, 1 DB, 1 SDB subroutines with/without parameter transfer Number of subroutines, max. 64 Programming language LAD Yes FBD Yes STL Yes Know-how protection User program protection/password protection Yes ; 3-stage password protection Connection method Plug-in I/O terminals Yes Dimensions Width 120.5 mm Height 80 mm Depth 62 mm Weights Weight, approx. Status 6ES7214-1AD23-0XB0 Page 6/ 6 360 g Jan 23, 2014 01/28/2014 subject to modifications © Copyright Siemens AG 2014
6ES7 214 1AD23 0XB0 价格&库存

很抱歉,暂时无法提供与“6ES7 214 1AD23 0XB0”相匹配的价格&库存,您可以联系我们找货

免费人工找货